Estimate only. This scales the label's population dosimetry (NETTER-1 adults, N = 20; NETTER-P adolescents, N = 8) to one patient's size and renal function with independent physician verified model calculations for detection of error before treatment (independent verification). It is not a substitute for post-therapy SPECT/CT dosimetry. Reference kidney doses assume the label's concomitant amino acid infusion for renal protection.
* Required. Enter weight, height and GFR to calculate doses.
| Organ | Limit (Gy) | Basis |
|---|
Limits follow Wahl et al., Normal-tissue tolerance to radiopharmaceutical therapies, the knowns and the unknowns, J Nucl Med 2021;62(Suppl 3):23S–35S. Radiopharmaceutical-therapy values are used where the article gives them (kidneys, red marrow, spleen, liver, lungs); external-beam values are used otherwise (heart, thyroid, urinary bladder wall) and are likely conservative for low-dose-rate PRRT. The pituitary gland is not covered by the article. Treat a flag as a prompt for review, not as a contraindication. Clear a value to remove that organ's limit.
| Organ | Gy/GBq | Mass × | TIA × | Absorbed dose (Gy) | vs limit | |
|---|---|---|---|---|---|---|
| Calc | Label | |||||
Doses are for one administration of the activity entered. Calc is this patient's adjusted dose; Label is the label's mean Gy/GBq × the same activity, with no patient adjustment. "vs limit" compares this dose with each organ's cumulative tolerance limit; the report also shows how many cycles at this activity would reach each limit. Under Gy/GBq, the label coefficient is shown beneath the adjusted one. n/a: the label gives no adult pituitary value (the adult calculation uses the adolescent value).
Each organ's dose worked through step by step with this patient's numbers. Ã/(f·A₀) is the time-integrated activity per unit of activity taken up by the organ (mono-exponential: 1.443 × Teff).
MIRD absorbed dose is the time-integrated activity in each source organ times the S value. For Lu-177, the β⁻ energy is deposited almost entirely locally, so the target-organ self-dose dominates and the dose scales inversely with organ mass.
D(organ) = Ã × S ≈ A₀ × τ × S D_pt = D_ref(Gy/GBq) × M_factor × TIA_factor × A₀ M_factor = scale_ref / scale_pt (weight, BSA, or none) λ_bio,ref = ln2/T_eff,ref − ln2/T_phys λ_bio,pt = λ_bio,ref × [(1 − w) + w × r] r = GFR_pt / GFR_ref T_eff,pt = ln2 / (ln2/T_phys + λ_bio,pt) TIA_factor = T_eff,pt / T_eff,ref
w is the fraction of each organ's biological clearance assumed to depend on renal excretion. Lower GFR keeps the radioligand in the blood longer, lengthening Teff and raising the dose. The ratio r is clamped at the minimum set above, because severe renal impairment (CrCl < 30 mL/min) was not studied.
| Organ | Ref Gy/GBq | Teff,ref (h) | Renal w | Mass scales by |
|---|
Inputs, dose summary, organ table, step-by-step MIRD calculation for every organ, method and references.